Study: Developing a unified OCT platform for glaucoma monitoring
UCLA researchers mapped macular OCT thinning against 10-2 visual field loss in 116 eyes across Spectralis and Cirrus devices.
A software platform developed at UCLA overlays macular OCT thickness maps with 10-2 visual field data to track glaucoma progression across 2 commercial OCT devices, according to a study published in Journal of Glaucoma. Vahid Mohammadzadeh, MD, and colleagues tested the tool on 116 patients from the Advanced Glaucoma Progression Study (AGPS).1 The same UCLA group previously identified the ganglion cell complex (GCC) as the strongest macular measure for detecting structural progression.2
“One of the major challenges in glaucoma management is that structural and functional data are often presented separately, making it difficult for clinicians to appreciate how the disease evolves over time,” Mohammadzadeh told Optometry Times in an exclusive statement. He described the platform as an early step toward a single record of how structure and function change across visits, rather than separate reports from each device.
What are the limitations of current OCT workflows?
The authors identified 3 gaps in how macular OCT is used for glaucoma care. First, devices from different manufacturers export data in different formats, and no single tool can display macular volume scans from all of them.1
Second, clinicians have no broadly accessible software for viewing macular thinning and field loss in a single display. Pairing the 2 is further complicated by anatomy: factors such as foveal shape and disc-to-fovea distance alter where central field points fall relative to macular ganglion cells in each eye.1
Lastly, current printouts place structural and functional results side by side for a single visit but do not show how either changes over time. Test-retest variability, which comes largely from perimetry, makes those trends harder to interpret at a glance.1
How was the platform developed?
AGPS enrolls patients with moderate to advanced glaucoma at UCLA’s Stein Eye Institute and follows them over time. Participants were aged 40 to 80 years, had best-corrected visual acuity of 20/50 or better, and had primary open-angle, pseudoexfoliative, pigmentary, or primary angle-closure glaucoma. The National Institutes of Health and Research to Prevent Blindness funded the work, and the authors reported no conflicts of interest.1
Every 6 months, participants received a clinical exam, macular imaging with Spectralis SD-OCT (Heidelberg Engineering) and Cirrus HD-OCT (Carl Zeiss Meditec), and 24-2 and 10-2 testing on the Humphrey Field Analyzer (Carl Zeiss Meditec). The Spectralis posterior pole protocol captures 61 horizontal B-scans across a 30×25-degree area, while the Cirrus Macular Cube spans 6×6×2 mm centered on the fovea.1
To make up for differences in scan area, orientation, and pixel density, the software resamples each thickness map onto a uniform grid and locates the fovea. It then rotates Spectralis data along the axis between the fovea and Bruch membrane opening, scales maps between devices, and shifts 10-2 test points to account for displacement of retinal ganglion cells near the fovea. Users can select the retinal layer, set resolution anywhere between 2×2 and 640×640, change layer opacity, choose baseline and follow-up dates, and view difference maps or an animation across visits.1
What were the study’s takeaways?
The researchers illustrated the platform with 2 patients followed for 4 to 5 years. In the progressing eye, difference maps showed a region of GCC thinning of at least 20 µm in the same area as a region of 10-2 sensitivity loss, while the stable eye showed no notable GCC change. Both eyes had some point-level 10-2 changes, which were more pronounced in the progressing eye.1
The evaluation was qualitative, and the study reported no statistical measures of structure-function agreement. So far, testing has been limited to Spectralis and Cirrus scans; supporting other devices would mean securing usable thickness exports, building calibration steps for each one, and confirming results independently.1
The tool cannot yet pull results directly from OCT devices or the Humphrey analyzer as tests are completed, a step required before clinic use, and it offers no statistical analysis of its own. A planned update will add rate-of-change estimates from Bayesian hierarchical modeling at 64 superpixels and 68 test locations, along with credible intervals and predictions for individual eyes.1
The platform remains a research tool and is not yet in clinical use.1 Its approach mirrors a step ODs managing moderate to advanced glaucoma can already take: reviewing 10-2 results alongside macular ganglion cell–inner plexiform layer or GCC maps to check whether areas of thinning and field loss coincide. The authors note a combined view could be most useful early in follow-up, before enough visits accumulate to calculate reliable rates of change.1
Mohammadzadeh noted viewing OCT thinning and the matching visual field loss side by side across visits gives clinicians a clearer picture of progression, and described the platform as an early step toward replacing separate reports from each device with a single record over time. “With further development and clinical integration, such technology could streamline imaging review, facilitate earlier recognition of disease progression, and ultimately support more personalized, data-driven treatment decisions aimed at preserving patients’ vision,” Mohammadzadeh stated.
This content was generated with the assistance of artificial intelligence.